Product Description
Switch Mode Power Supply
Owing to our rich industrial expertise and skills, we are renowned as one of the most profound manufacturers and suppliers of Switch Mode Power Supply. These switch modes efficiently satisfy all the power related needs. This Switch Mode Power Supply system is renowned in the industry for its exclusive features such as rugged design and high performance. In order to meet the diverse needs of our customers, these power supply systems are available in different specifications and that too at reasonable prices.
Specification
-
Standard SMPS
-
Input: 220VAC (110 - 265VAC) working voltage range.
-
Outputs: 5V 2A, 5V 5A , 5V 10A , 12V 3A, 12V 6A , 12V 10A, 24V 2A, 24V 5A , 24V 10A.
Features
-
Universal AC input/ Full range
-
High Efficiency, and High reliability
-
Output protections: SCP/OVP/OPP/OLP
-
Wide operating ambient temperature (-20oC~70oC)
-
All using 105 oC long life electrolytic capacitors.
-
100% full load burn-in test
-
2 years warranty
Model |
Output | DC Output | As per Requirement |
Rated Current | As per Requirement |
Ripple and Noise Note 2 | 80mV |
Working Temp Range | -20 to 50 oC |
Voltage ADJ. Range | +10% of rated output voltage |
Voltage Accuracy | +2.0% |
Line Regulation | +0.5% |
Load Regulation | +2.0% |
Set-up Time | <2.0S (120Vac input, Full load); <1.0S (230Vac input, Full load) |
Hold up Time | >14mS(120Vac input, Full load); >30mS(230Vac input, Full load) |
Temperature Coefficient | +0.03%/oC |
Overshoot and Undershoot | <5.0% |
INPUT | Voltage Range | 88Vac~264Vac |
Frequency Range | 47Hz~63Hz |
Efficiency ( Typical) | 70%(120Vacinput |
| 71%(230Vacinput |
AC Current (max.) | 0.7A -5A |
Inrush Current (Typical) | 130% of rating |
Leakage Current | Input"output:<0.25mA Input" PG:<0.75mA |
Protection | Over Power | 105%~150% of rated output current, hiccup mode,Constant power |
Over Current | 105%~150% of rated output current, hiccup mode,Constant current |
Over Voltage | 105%~150% of rated output voltage, Constant Voltage ,re-power on to recover |
Shorted Circuit | Long-term mode, auto recovery |
Environment | Operating amb. Temp. & Hum. | -20 to 50 oC |
| Storage Temp. & Hum. | 10%~95%RH No condensing |
Safety & Emc Note 3 | Safety Standards | UL60950-1; EN60950-1: 2006 |
Withstand Voltage | Primary-Secondary:3.0KVac; =S10mA .Primary-PG:1.5KVac; =S10mA. Secondary-PG:0.5KVDC;:S10mA. |
Isolation Resistance | 5 to 100M ohms |
EMI Conduction&Radiation | Compliance to EN55022(CISPR22) Class B |
Harmonic Current | Compliance to EN61000-3-2,-3 |
EMS Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteria A |
Others | MTBF (MIL) | Mil grade |
Dimension (LxWxH) | Depending on rating requirement |
Packing | Cardboard packeging |
Cooling method | Cooling by free air convection |
Note | 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25% of ambient temperature. 2. Measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. |